Yes, all HIBLOW pumps can operate on either 50hz or 60hz. Thank you. Hiblow HP-80 0119 septic air pump is a model of Hiblow that is used in specific septic systems. M-F: 7a-5p Sat: 7a-10a Sun: closed. Rebuilding is typically a fraction of the cost of a new system. The Hiblow HP60 & HP80 Air Filter is designed to keep dirt and particles from entering the internal pump. Seller assumes all responsibility for this listing. Hook your air pump back up to your system! Truly, they are known for their longevity and premium grade materials. Replacement gasket for Hiblow models HP100 & HP120. NOTE: DO NOT DISCARD BOLTS, THEY WILL BE REUSED. This alarm will sound to alert you of any issues regarding your air pump. Using a 7mm (1/4in) wrench or nut driver remove the U-lock nuts that hold the diaphragm to the magnetic rod block. Techno Takatsuki Co Ltd|Hiblow Europe|Hiblow Korea. Hiblow is one of the most popular Septic Air Pump brands on the market due to its reliability and ease of use. The alarm can be silenced while you fix the issue, but a red light will stay on until the issue is solved. Quick delivery, product as described in original box and packaging. This gasket is located between the cover and the filter. If your pump runs and hums but does not produce air, you may just need a rebuild kit. In addition to failing quickly, they can be noisy, and will often destroy the inside of the pump. You must have JavaScript enabled in your browser to utilize the functionality of this website. If the air pump is over 10 years old, we would recommend replacing the air pump. When the diaphragms fail, the pump will shut off and your alarm should sound. When your system stops working, may be able to rebuild it, instead of buying a new septic system. For detailed instillation instructions click here. View cart for details. (812) 636-7386 Use single quotes (') for phrases. During this time, it will require little maintenance. Drain Fields | Secure the diaphragm on the other side and tighten the U-lock nut with the box driver. Please note that the performance will be different depending on the frequency applied, so refer to the performance curves for information on each. While these aerators are the longest lasting on the market they do get worn out over time. This website is owned independently separate from Hiblow USA, Techno Takatsuki, LLC, 3.6 psi Max Continuous Operating Pressure. The screw is designed so that the nut will turn freely when it is properly fastened. For more information, go to www.P65Warnings.ca.gov. This ensures your product can have a long life. Secure the upper housing with the bolts that were removed in STEP 1. Nevertheless, they have been known to power systems around the world for nearly 100 years. Order by phone Call us toll free: (800) 778-1540 Weekdays 8:00AM to 4:30PM (CST). All rights reserved. Replace the sound absorber removed in STEP 2 and place the upper housing back on the body. If your pump runs and hums but does not produce air, you may just need a rebuild kit. The Hiblow HP-60and HP-80 diaphragm replacement kit is the standardrebuild kitand includes the necessary components for replacing the diaphragms on your Hiblow model. Installed rebuild kit two days ago. The typical Hiblow HP-80-013A Septic Air Pump should last 10 to 12 years. Remove one of the diaphragms from the actuating rod and pull out the other diaphragm with the magnetic rod. They are made from inferior materials and do not fit to specification. Something went wrong. Using a phillips screwdriver. HIBLOW HP-60/80 Rebuild/Repair Kit -Genuine Factory Certified Free Fast Shipping. The kit includes: two diaphragm blocks, two diaphragm heads, a replacement filter, a replacement safety screw and hardware. It has low vibration and pulsation and starting current, so you should not hear any background buzzing in your home. For wastewater applications, always contact your treatment system manufacturer before altering any aeration settings. The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. Overall, you want to keep any additional heat to a minimum and you will have a happy pump with a long life. A professional service provider may also be able to determine the HIBLOW pump model you need. Most likely the nut attaching the diaphragm to the rod was either not installed, or not tightened snug enough. The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. Draw a new safety screw through the hole in the SP switch and the holes in the L shaped lever and spring contact. It has. Not to mention rebuild kits are available to prolong the lifespan of your pump. Inspections | This gasket is located between the cover and filter. Service Agreements | Refresh your browser window to try again. An electronic copy of the owners manual can be found on the Support tab of our website. Hiblow is known for providing top-of-the-line septic aerators. A trick to getting the nut on the safety screw is to use a pair of needlenose pliers to hole the nut in place while you turn the screw into it. a replacement filter, a replacement safety screw and hardware. In a garage, shed, or crawlspace are all good options. TGWasteWater uses cookies to give you the best shopping experience. Make sure to check the diffusers in your pond or wastewater system to make sure they are not excessively clogged. Replacement base plate gasket for Hiblow models HP100 & HP120. (618) 783-2416 This kit includes 2 diaphragms with mounting blocks, 2 heads with air valves, a replacement air filter, and a replacement safety screw. The Hiblow HP-80-013A Septic Air Pump comes standard with an alarm attached. The Hiblow HP-80-013A Septic Air Pump is known for its quiet operation. 2022 HIBLOW USA. An inverter would be needed in order to use a HIBLOW linear pump in a system powered by DC. Site design by DesignHub. Septic Pumping | Hiblow HP-80 linear septic air pump aerator - 2-year warranty. Did you buy a knock off repair kit? Remove the four screws that hold the chamber block and the casing block on both side (4 screws on each side). The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. The Complete Kit includes everything you need to rebuild your Aerator. As long as the system has not been rebuilt before, and isnt showing signs of rust, you can usually rebuild. Filtration | Use spaces to separate tags. Please be sure to disconnect power from the unit before completing repairs. Septic Care, Rex Vault Service The Hiblow HP-80-013A is UL rated for outdoor use. Replacement base plate gasket for Hiblow models HP60 & HP80. 807 E. Jourdan St., Newton, Illinois 62448 Knock off kits are common on Amazon and eBay. If you bought your Hiblow HP 80 from us it is covered by a 2 year warranty. {"modules":["unloadOptimization","bandwidthDetection"],"unloadOptimization":{"browsers":{"Firefox":true,"Chrome":true}},"bandwidthDetection":{"url":"https://ir.ebaystatic.com/cr/v/c1/thirtysevens.jpg","maxViews":4,"imgSize":37,"expiry":300000,"timeout":250}}. Home HP Alarm Series Hiblow HP-80-013A Septic Air Pump. Don't waste your money buying a new aerator when you can fix the one you have for a fraction of the cost. Highly recommended. The HP 60 and HP 80 are diaphragm operated aerators. The Hiblow HP60/80 (#80PC000042) rebuild kit is compatible with all of the following models: Below are instructions on how to install this repair kit in a Hiblow air pump. Stop tightening when this happens. However, after 4 to 6 years, your system may need to be rebuilt. Replacement gasket for Hiblow models HP60 & HP80. Septic Risers | Find out more about cookies and how you can refuse them. Using a phillips screwdriver could cause you to strip out the bolts. ORDER ONLINE ANYTIME OR CALL OUR SALES STAFF TO PLACE AN ORDER BETWEEN 8:00 AM to 4:30 PM CT MON-FRI TOLL FREE: (877)-925-5132 MOST ORDERS PLACED BEFORE 2 PM CST WILL BE SHIPPED THE SAME DAY, 2 Diaphragm Heads with Factory Installed Air Check Valves, Hoot Troy Air H365, H450, H500, LA500, H600, 7mm or 1/4in Wrench, Socket, or Nut Driver. Reconnect the L-Tubes to the diaphragm head on each side. The Hiblow HP40 Diaphragm Kit can be used to repair/rebuild the Hiblow model HP40. A cool and dry location out of the sun is ideal. Fasten the screw with the nut supplied and tighten with a flathead screwdriver. It comes with. Installing the HP 60 and HP 80 rebuild kit is easy and requires only a screwdriver. The Hiblow HP100 & HP120 Diaphragm Kit can be used to repair/rebuild the Hiblow models HP100 & HP120. Refer to the owners manual for instructions on how to reset the safety slide switch. Learn How To Install A Hiblow Rebuild Kit. Pull off the white sound absorber from around the internal pumping unit and disconnect the L-TUBES on each end from the diaphragm head. Over time, some internal parts may wear out. If your pump runs and hums but does not produce air, you may just need a rebuild kit. Grease Trap Pumping, Norweco Parts | Install the heads on both sides with the 4 screws that were removed originally. The kit includes: two diaphragm blocks, two diaphragm heads, one replacement air filter, and hardware. Finally separate the diaphragm mounting block and rod. Thank you so much! quick delivery, product is as advertised. We have numerous distributors across North America that can supply you with both pumps and repair parts. Septic Tank Parts|7059 Highway 47 Union, Mo 63084, Hiblow HP50/60/80 Dual Port Base Plate Gasket. Please email or call for your closest or most convenient option. NOTE: DO NOT DISCARD SCREWS, THEY WILL BE REUSED. No, the operating principle of our linear pumps utilize Alternating Current (AC) to shuttle the rod back and forth, and thus create pressure or vacuum. That depends on the application. The kIt includes: two diaphragm blocks, two diaphragm heads, one replacement air filter, and hardware. This ensures you completely fix the problem at hand. It also has thermal protection and over-pressurization protection. Replacement base plate gasket for Hiblow models HP50W/HP60W/HP80W. If upper pump housingis difficult to remove due to the heavily stuck internal seal, pry it open by inserting the tip of a flat-head screwdriver into the clearance between the exhaust nozzle and upper housing. Aeration | The warning listed above is provided to California consumers to ensure compliance with California Proposition 65. Please contact the manufacturer of your treatment system to ensure the correct sizing of the air pump for your specific unit. M-F: 7a-5p Sat: 7a-10a Sun: closed, Rex Vault Service If it is out of warranty or not purchased through TG Waste Water than a HP 60/HP 80 or HP 100/HP 120 Rebuild kit is the next best thing. The Hiblow HP-80-013A also features an oil-less contamination free design, which will keep your air pump clean and free of unwanted germs or dirt. It is recommended the filter be cleaned every six months and replaced every year. Over time, some internal parts may wear out. Over time, some internal parts may wear out. If it must be installed outside, it is best to ensure that the pump gets good ventilation and is not in direct sunlight. Remove all the bolts from the four corners. If your pump runs and hums but does not produce air, you may just need a rebuild kit. Submersible Pumps | Fast Ship, Just what I needed at a fair price. Use new U-lock and washer that come with the kit to prevent loosening and causing failure of the pump. The kit includes: two diaphragm blocks, two diaphragm heads. Over time, some internal parts may wear out. If you continue to use our services, we will assume that you agree to the use of such cookies. HIBLOW linear pumps are not dual voltage, so please check the data label on the pump and only apply the correct voltage as a power source. Shipping was very fast! the 17/07/2018. Insert the actuating rod in accordance with the gap of the frame. Your HP series air pump was likely jostled during shipping and the safety slide switch has moved to the inoperable position which deactivates the electric motor. In fact, Hiblow's aerators have been put to the test across the country and proven to last long lives. Copyright 2005-2022 Septic Tank Parts Online Store. The diaphragms normally need to be replaced every 4 to 6 years depending on the application. - Top Rated Plus - opens in a new window or tab, - eBay Money Back Guarantee - opens in a new window or tab, - for PayPal Credit, opens in a new window or tab, Learn more about earning points with eBay Mastercard, - eBay Return policy - opens in a new tab or window, - eBay Money Back Guarantee - opens in a new tab or window. This is done easier using a 7mm or 1/4in socket instead of a phillips screwdriver. Order By Phone (800) 778-1540 or (636) 583-1608 M-F: 8:00AM to 4:30PM (CST). Make sure the gapes between the actuating rod and the electromagnet are even. SepticTankParts.com is an independent seller of replacement septic system parts for numerous original manufacturers and the use of the names of the original manufacturers, their models, types, part number and other descriptive product information is only for the purpose of aiding customers in cross-referencing the appropriate SepticTankParts.com part. Copyright 1995-2022 eBay Inc. All Rights Reserved. The quiet septic air pumps operate with low power consumption and have an extremely long lifespan. The additional backpressure of clogged diffusers may be exceeding the design pressure for the pump model you are using. Install the new diaphragm on the actuating rod before inserting the rod back into the pump. So far, so good.. the 08/06/2018, the 13/03/2018, the 06/01/2018, the 07/08/2017, Shaft Style Septic Aerators - Jet/Norweco Replacements, View All Control Panels & Control Panel Parts, Hiblow HP 80 Pond or Septic Air Pump UL APPROVED HP80 HP 80, SPI BIO-A Double Light Control Panel for Aerobic Septic Systems - 50B138, SPI BIO-B Double Light Control Panel for Aerobic Septic Systems - 50B006. 714 W. Elnora St., Odon, Indiana 47562 WARNING: These products can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. JavaScript seems to be disabled in your browser. The Hiblow HP60 & HP80 Diaphragm Kit can be used to repair/rebuild the Hiblow models HP60 & HP80. The Hiblow HP100 LL & HP120 LL Diaphragm Kit can be used to repair/rebuild the HP100 LL & HP120 LL models. Controls & Alarms | You can find a rebuild kit on Wholesale Septic Supply.
Call Now
high back patio chair covers